Shaft layout
Values | |
---|---|
SD / SW | see dimensions pages |
SH | CH + 1180 mm (1 m/s) |
min. 3615 mm (1.6 m/s) | |
min. 3735 mm (1.75 m/s) | |
SH red. | CH + 400 mm (1 m/s) |
SP | min. 1000 mm (1 m/s) |
min. 1130 mm (1.6 m/s) | |
min. 1360 mm (1.75 m/s) | |
SP red. | min. 450 mm (1 m/s) |
TH | max. 40 m/min. 2900 mm (1 m/s) |
max. 75 m (>1 m/s) | |
HST | min. DH+450 mm / max. 11 m |
HST2 | min. 500 mm |
CH | 2100 / 2200 / 2300 mm |
DH | 2000 / 2100 mm |
DW | 800 / 900 / 1000 mm |
Entrance | Single and double entrance (180°) |
Type | L2, side-opening with 2 panels |
Key | |
---|---|
SD | shaft depth |
SW | shaft width |
SH | shaft head |
SP | shaft pit |
red. | reduced shaft head / shaft pit |
TH | travel height |
HST(2) | min. height between floors |
CH | cabin height |
CW | cabin width |
CD | cabin depth |
DH | door height |
DW | door width |
FFL | finished floor level |
UFL | unfinished floor level |
Note: All shaft dimensions with standard tolerances. The values shown correspond to a generic installation under ideal circumstances. During the planning phase, all applicable regulations stipulated by relevant notified bodies and all applicable national regulations should be considered.